The best vacuum pumps for installing a mini split

Five two-stage pumps that suit a home ductless install, ranked on rated vacuum, weight, oil handling and how well they handle a long extension cord.

Any mini split joined with flare fittings has air and moisture in the line set and indoor coil until a vacuum pump pulls them out. The manual we used as our reference, Daikin's for its 2MXM to 4MXM outdoor units, asks for a vacuum below 500 microns held for at least an hour before you open the service valves. A home line set doesn't hold much, so four to eight CFM is plenty. Care more about a deep rated vacuum, oil that stays clean, and a pump you can actually carry to the outdoor unit. Pre-charged quick-connect line sets are sealed at the factory and skip all of this.

1

Fieldpiece VP87

Best overall

An 8 CFM two-stage rotary vane pump on a 3/4 HP brushless DC motor, rated to 15 microns. Four inline ports (one 1/4 inch, two 3/8 inch, one 1/2 inch) let a hose run straight to the service valve without adapters.

Its RunQuick system lets you drain and refill oil without stopping the pump, and a backlit reservoir shows you when the oil's gone cloudy. Fieldpiece rates it to keep working at 85 volts. That's often what you get at the far end of a long extension cord. It's also listed as certified for A2L refrigerants.

Watch out: At 27 lb it's more pump than a single-zone line set really needs, and only the Robinair is heavier to haul up a ladder.

Fieldpiece VP87 product page
2

NAVAC NP4DLM

Best cordless

A 4 CFM dual-stage pump rated to 15 microns that runs from an 18V, 9Ah lithium battery. NAVAC quotes up to an hour of continuous running on one charge, and the whole unit weighs 15.4 lb with the battery fitted.

Inlets take 1/4, 3/8 and 1/2 inch flares and it holds 8.8 oz of oil. There's a gas ballast and an isolation valve. The wall-power adapter, the NAPS1, is sold separately.

Watch out: One hour of battery is exactly the minimum evacuation time in the Daikin manual. That leaves nothing for a line that's slow to dry, so budget for a second battery or the adapter.

NAVAC NP4DLM product page
3

CPS VP6D

Deepest rated vacuum

A 6 CFM, two-stage pump on a 1/2 HP motor, which CPS rates as low as 10 microns, the deepest figure in this group. It switches between 110 to 120V and 220V, weighs 22.5 lb and holds 14 oz of oil.

Ports are 1/4 inch SAE, 3/8 inch SAE and 1/2 inch ACME, and a gas ballast valve helps clear moisture on the way down.

Watch out: Ultimate-vacuum ratings are measured on a pump with its inlet capped. Hoses, valve cores and water in the line decide what you'll really read at the unit. A 10 micron pump doesn't mean a 10 micron system.

CPS VP6D product page
4

Yellow Jacket SuperEvac PLUS II

Largest oil reservoir

Yellow Jacket's current brushless line comes in 4, 6, 8 and 11 CFM. The 6 CFM model, 93760, weighs 25.9 lb and holds 36 oz of oil. That's several times the reservoir of the pumps above it, so it can soak up more moisture before the oil needs changing.

The maker describes the range as field rated to 15 microns.

Watch out: The spec table doesn't list ultimate vacuum or input voltage per model, and the older SuperEvac 935xx pumps are discontinued. Check the model number on the box.

Yellow Jacket SuperEvac PLUS II page
5

Robinair VacuMaster 15500

Plain and proven

A 5 CFM two-stage pump with a 1/3 hp motor and a rated ultimate vacuum of 35 microns, still far below the 500 micron target. The intake takes a 1/4 inch male flare and 3/8 inch ACME, with an adapter supplied for 1/2 inch ACME hoses.

It's the old-school choice. No battery, no running oil change, nothing extra to break.

Watch out: It's the heaviest here at 28 lb and has the smallest oil reservoir, 7.5 oz, so expect to change oil sooner on a wet line set.

Robinair VacuMaster 15500 page

What the installation manual asks for

The Daikin manual for its 2MXM, 3MXM and 4MXM outdoor units lays out the order. First, pressure-test the line set through the service ports to 604 psi, no higher (installers use dry nitrogen for this). Hold it at least an hour. Daikin recommends 24 hours. Then hook up the gauge manifold, open both sides, and pull it below 500 microns for at least an hour.

Next, close the manifold, shut off the pump and wait four to five minutes to make sure the reading doesn't climb back. Only then do you open the stop valves. Other brands publish their own numbers. Follow the ones in your unit's manual.

How large a pump you need

CFM is free-air displacement, meaning how fast the pump moves air at normal atmospheric pressure. It tells you little about the last stretch below a few thousand microns. Down there, a skinny hose and the core in a service port slow things more than the pump does. For a home line set, four to eight CFM is enough. A deeper rated vacuum and clean oil help more than extra CFM.

Common questions

Does every mini split need a vacuum pump?

Any one joined with flare fittings does, because the line set is full of air and moisture until it's evacuated. Pre-charged quick-connect systems are the exception. The refrigerant stays sealed from the factory, so there's nothing to evacuate.

How long should I run the vacuum pump on a mini split?

Until the micron gauge drops below the target in your manual, then for however long it says. The Daikin manual we cite wants below 500 microns for at least one hour, then a few minutes with the pump off to make sure the reading holds.

Can I tell when it is done from the pump's own gauge?

No. A compound gauge reads in inches of mercury, and 500 microns is about 0.02 inHg. You can't see that on a dial. You need a digital micron gauge to confirm you hit the target and held it.