Best Mini Split Brands

Home/Flaring tools

The best flaring tools and torque wrenches for mini splits

Most flare leaks come from a bad flare or a nut tightened by feel. Here are three flaring tools and the torque wrench to go with them.

A flare joint seals on the copper cone itself. So the flare has to be smooth and the right size, and the nut has to go to a number, not a feel. An eccentric-cone tool with a clutch handles most of the flare for you. A torque wrench with open-end heads handles the nut. The Daikin manual we reference spells it out: cut square, deburr with the cut facing down, slide the nut on before flaring, oil only the inside of the flare, spin the nut three or four turns by hand, then finish with a torque wrench.

1

Yellow Jacket 60295

Best manual flaring tool

An eccentric-cone tool for 3/16 to 3/4 inch tubing. The off-center hardened cone rolls the copper into a 45 degree flare instead of forcing it, so the walls come out even. A built-in clutch lets go before you over-torque it.

It comes with Yellow Jacket's 60297 flare sizing gauge. Yellow Jacket says today's higher-pressure systems need deeper flares than older tools made.

Watch out: Yellow Jacket has said its older red-handled 60280 makes flares smaller than some R-410A equipment makers want. Buy by model number.

Yellow Jacket 60295 product page
2

CPS FT800FN

Best with a ratchet

It covers 3/16, 1/4, 5/16, 3/8, 1/2, 5/8 and 3/4 inch tubing with a clutch-driven feed screw that breaks away at a set torque. A 3/8 inch square drive in the yoke takes the included ratchet. Your wrist will thank you on the bigger sizes.

CPS lists it for R-410A systems, ships it in a polyethylene case and covers it for one year.

Watch out: The CPS page doesn't state the flare angle. Mini split fittings are 45 degree SAE flares, so check your first flare against the fitting or a flare gauge.

CPS FT800FN product page
3

NAVAC NEF6LM

Best powered

A battery flaring tool with five dies from 1/4 to 3/4 inch. NAVAC rates it at more than 100 flares per charge on a 7.4V, 2Ah battery. The tool weighs 2.9 lb.

The kit includes the dies, battery, charger, NAVAC's NFG1 flare gauge and a hard case. It's handy where the line set meets the indoor unit in a tight spot behind the wall.

Watch out: NAVAC's page doesn't give the flare angle or which refrigerants it's rated for. Check each flare with the included gauge.

NAVAC NEF6LM product page
4

Yellow Jacket 60650 / 60652 torque wrench

The tool you need with any of them

An adjustable wrench covering 7.4 to 59 ft-lb (10 to 80 N·m), accurate within 4 percent to ISO 6789 with any head. The 60650 kit includes 17, 22, 24, 26, 27 and 29 mm open-end heads. The 60652 adds 16 and 21 mm.

That covers every flare nut value in the Daikin list below, up to the 55.6 ft-lb top end for 5/8 inch line.

Watch out: Match the head to the flare nut exactly. The wrong one can round off the nut and throw off the reading.

Yellow Jacket precision torque wrench page

Flare nut torque from the manual

Here are the flare nut values from the Daikin installation manual for its 2MXM to 4MXM outdoor units. A 1/4 inch nut takes 10.5 to 12.75 ft-lb (14.2 to 17.2 N·m). A 3/8 inch nut takes 24.1 to 29.5 ft-lb (32.7 to 39.9 N·m). A 1/2 inch nut takes 36.5 to 44.5 ft-lb (49.5 to 60.3 N·m). A 5/8 inch nut takes 45.6 to 55.6 ft-lb (61.8 to 75.4 N·m).

The same manual covers the caps too: 12.6 to 15.4 ft-lb for valve caps with 3/4 inch (19 mm) flats, 16 to 20.25 ft-lb for 7/8 inch (22 mm) flats, and 8 to 10.9 ft-lb for service port caps. Other brands publish their own values. Your unit's manual wins.

Setting the tube in the die

How far the copper sticks up above the die decides how big the flare comes out. Daikin gives 0 to 0.020 inch for a clutch-type tool made for R-32 or R-410A, 0.039 to 0.059 inch for an older rigid clutch-type tool, and 0.059 to 0.079 inch for a wing-nut type. Set the tube by your own tool's instructions or its flare gauge. Then check the flare against the fitting before it goes on.

Common questions

Can I reuse a flare that has already been tightened?

The Daikin manual says don't reuse a joint that's been used once. If a flare's been tightened and taken apart, cut it off and make a new one.

Should I put oil on a mini split flare?

Only on the inside face of the flare, and only refrigeration oil that suits the refrigerant. Daikin warns against oiling the outside or the nut, since that makes it easy to over-tighten. No mineral oil, either.

Do I really need a torque wrench for flare nuts?

Yes. The manual calls for one, and the window's narrow: 10.5 to 12.75 ft-lb on a 1/4 inch nut. Too loose and it leaks. Too tight and you can crack the nut or thin the flare until it leaks later.